Professional FM200 Fire System Automatic Refilling Equipment for Industrial Safety

Ürün Ayrıntıları

Menşe yeri: Guangzhou, Çin

Marka adı: XINGJIN

Sertifika: CCC,CAC,ROHS

Model numarası: XJ-QEO-006

Ödeme ve Nakliye Şartları

Min sipariş miktarı: 1 Set Sistemi

Fiyat: Pricing based on quantity

Ambalaj bilgileri: Kabarcık torbası veya kağıtlı ahşap kutu veya kontrplak dış kutu

Teslim süresi: Ürün miktarına göre

Ödeme koşulları: T/T, L/C

Yetenek temini: 3000 takım/ay

En İyi Fiyatı Alın
Ürün Ayrıntıları
Vurgulamak:
Uygulanabilir yangın söndürme ajanı:
Perfloroheksanon, azot
Maksimum dolum basıncı:
6.0 Mpa
Azot dekompresyon aralığı:
0 ~ 10 MPa ayarlanabilir (yaygın olarak kullanılan: 4.2 MPa, 5.6 MPa)
İlaç çıktı basıncı:
0 ~ 3.6 MPa
Vakum derecesi:
≤ -0.09 MPa
Basınç alarmını doldurma:
0 ~ 10 MPa (ayarlanabilir, ayarlanan değeri ulaşırken alarm ışığı açılacaktır)
dolgu yoğunluğu:
≤ 1420 kg/m³
Doğruluk doldurma:
±% 0.5
Ortam Sıcaklığı:
0 ~ 50 ℃
Güç Gereksinimleri:
AC 220V,50Hz
Ekipman Boyutu:
720 × 800 × 1280 mm (koşucu hariç)
Harici bağlantı iş parçacığı:
Reaktif girişi ve çıkış ve azot arayüzü için dişler: M22 × 1.5
Uygulanabilir yangın söndürme ajanı:
Perfloroheksanon, azot
Maksimum dolum basıncı:
6.0 Mpa
Azot dekompresyon aralığı:
0 ~ 10 MPa ayarlanabilir (yaygın olarak kullanılan: 4.2 MPa, 5.6 MPa)
İlaç çıktı basıncı:
0 ~ 3.6 MPa
Vakum derecesi:
≤ -0.09 MPa
Basınç alarmını doldurma:
0 ~ 10 MPa (ayarlanabilir, ayarlanan değeri ulaşırken alarm ışığı açılacaktır)
dolgu yoğunluğu:
≤ 1420 kg/m³
Doğruluk doldurma:
±% 0.5
Ortam Sıcaklığı:
0 ~ 50 ℃
Güç Gereksinimleri:
AC 220V,50Hz
Ekipman Boyutu:
720 × 800 × 1280 mm (koşucu hariç)
Harici bağlantı iş parçacığı:
Reaktif girişi ve çıkış ve azot arayüzü için dişler: M22 × 1.5
Ürün Tanımı

Heptafluoropropane fire extinguishing agent filling equipment


Product Overview:
  
Heptafluoropropane fire extinguishing agent filling equipment is a professional device that integrates high efficiency, safety and precision, and is suitable for
  Heptafluoropropane fire extinguishing agent filling. The equipment is equipped with nitrogen pressure reduction, filling pressure alarm, vacuum pumping system and weight reporting
  The alarm node reserves interfaces to support multiple gas cylinder specifications, ensuring the airtightness and accuracy during the fire extinguishing agent filling process
Professional FM200 Fire System Automatic Refilling Equipment for Industrial Safety 0

Technical Parameter:

Project Parameter
Suitable Extinguishing Media FM200(HFC-227ea),Nitrogen
Maximum Filling Pressure 5.6 MPa
Nitrogen Pressure Reduction Range 0~ 10 MPa adjustable (commonly used: 2.5 MPa, 4.2 MPa, 5.6 MPa)
Drug Output Pressure 0~3.6 MPa
Vacuum Degree ≤ -0.09 MPa
Filling Pressure Alarm 0~ 10 MPa (Adjustable to set value, alarm warning light on)
Filling Density ≤ 950 kg/m³
Filling Accuracy ±0.5%
Ambient Temperature 0~50℃
Power Requirements AC 220V ,50Hz
Equipment Size 720×800×1280 mm (Excluding the wheel)
External Connection Thread Drug inlet and outlet threads and nitrogen interface: M22 × 1.5
Other Reserved weight alarm indicator interface (requires external intelligent electronic weighing device)

Professional FM200 Fire System Automatic Refilling Equipment for Industrial Safety 1

 Equipment valve body function:

F1 pressure reducing valve Control the pressure of nitrogen entering the system to ensure stable and safe filling process.
F2 pressure relief valve

Release excess pressure in emergency situations to protect equipment and gas

cylinders from high pressure damage.

F3 Pharmaceutical Storage Valve Control the pipeline for the flow of fire extinguishing agent from the storage tank to the filling cylinder.

 

 

 

F4 nitrogen storage valve Control the entry of nitrogen from the storage tank into the equipment pipeline to provide pressure for the filling of fire extinguishing agents.
F5 gas cylinder valve

Used to connect fire extinguishing agent cylinders and control the opening or closing

of cylinder fluid pipelines.

F6 vacuum valve Used to open or close the air inside the extracted gas cylinder, reduce the pressure inside the cylinder, and ensure the purity of the fire extinguishing agent filling.


FAQ:
Q: Are you a trading company or a manufacturer?
A: We are both a manufacturer and a trading company. We have owned our own factory for nearly 15 years and are committed to providing high-quality service to our overseas customers.

Q: Can you do OEM production?
A: We accept all OEM orders. Simply contact us with your design proposal, and we will provide you with a reasonable price as soon as possible.

Q: How do you ensure product quality?
A: We have TUV/SGS/ISO quality control systems and strictly adhere to them. We have a professional quality inspection team, and each packer conducts a final inspection according to the quality inspection instructions before packaging.

Q: What is the delivery time?
A: Depending on the minimum order quantity, we ship within 10-15 business days after receiving the deposit. 20-foot container orders typically take 30-35 days to fulfill.
Q: Besides filling machines, do you offer other conventional firefighting equipment?
A: Of course. We offer a full range of professional firefighting equipment, from sound and light alarms to smoke exhaust valves, as well as FM200, CO2, and Novec1230 fire suppression systems. Feel free to contact us!
Please inquire about the specific delivery time based on your order quantity.

Why choose us?​
Professional FM200 Fire System Automatic Refilling Equipment for Industrial Safety 2